Difference between revisions of "POMS"

From Mu2eWiki
Jump to navigation Jump to search
Line 22: Line 22:
 
  https://dbdata0vm.fnal.gov:8444/mu2e_ucondb_prod/app/... - cached, external and internal access
 
  https://dbdata0vm.fnal.gov:8444/mu2e_ucondb_prod/app/... - cached, external and internal access
 
  http://dbdata0vm.fnal.gov:9091/mu2e_ucondb_prod/app/... - cached, internal access only
 
  http://dbdata0vm.fnal.gov:9091/mu2e_ucondb_prod/app/... - cached, internal access only
 +
 +
 +
FCL files are saved to the UconDB in dedicated folders. It's not possible to use dots in the name of the database folders, so we replace with underscores, as in:
 +
https://dbdata0vm.fnal.gov:9443/mu2e_ucondb_prod/app/UI/folder?folder=cnf_mu2e_pot_db_test_v12_fcl
 +
 +
The POMS FCL stages take care of creating the folders and saving the FCL files. The SAM location of the files stored in the database looks like this:
 +
 +
$ samweb locate-file cnf.mu2e.POT.db_test_v12.001201_00000001.fcl
 +
dbdata0vm.fnal.gov:/mu2e_ucondb_prod/app/data/cnf_mu2e_POT_db_test_v12_fcl
  
 
==References==
 
==References==

Revision as of 01:32, 18 December 2021

Introduction

The Production Operations Management Service (POMS) is a computing division tool that helps users to run large and complex grid campaigns. It provides

  • control scripts and GUI interface
  • chaining of multiple stages of a grid campaign
  • re-submission of failed jobs
  • analysis of logs and database entries for results

Currently (8/2021), we are only using POMS for Production as a test. Users can use Mu2e tools

project-py is s python scripts which provides a command line interface.


UconDB

mu2e_ucon_prod - created 11/2021 to help with MDC2020

  • database mu2e_ucon_prod owned by nologin role mu2e_ucon_prod;
  • Kerberos-authenticated roles: brownd kutschke srsoleti
  • md5 authenticated role 'mu2e_ucon_web' (for POMS)
  • port is 5458 (on ifdbprod/ifdb08)
https://dbdata0vm.fnal.gov:9443/mu2e_ucondb_prod/app/... - not cached, external and internal access
http://dbdata0vm.fnal.gov:9090/mu2e_ucondb_prod/app/... - not cached, internal access only 
https://dbdata0vm.fnal.gov:8444/mu2e_ucondb_prod/app/... - cached, external and internal access
http://dbdata0vm.fnal.gov:9091/mu2e_ucondb_prod/app/... - cached, internal access only


FCL files are saved to the UconDB in dedicated folders. It's not possible to use dots in the name of the database folders, so we replace with underscores, as in: https://dbdata0vm.fnal.gov:9443/mu2e_ucondb_prod/app/UI/folder?folder=cnf_mu2e_pot_db_test_v12_fcl

The POMS FCL stages take care of creating the folders and saving the FCL files. The SAM location of the files stored in the database looks like this:

$ samweb locate-file cnf.mu2e.POT.db_test_v12.001201_00000001.fcl
dbdata0vm.fnal.gov:/mu2e_ucondb_prod/app/data/cnf_mu2e_POT_db_test_v12_fcl

References