Datasets-SU2020: Difference between revisions

From Mu2eWiki
Jump to navigation Jump to search
No edit summary
Line 9: Line 9:


{|class="wikitable"
{|class="wikitable"
!style="text-align:center" | Dataset                   || N(generated events) signal-only  || N(events) mixed || comments
!style="text-align:center" | Dataset                               || N(generated events) signal-only  || N(events) mixed || STNTUPLE dataset || comments
|-                         
|-                         
                           | CE (mu-Al --> e-Al)       ||    1,000,000                   ||  2,000,000   ||  
                           | CE (mu-Al --> e-Al)                   ||    1,000,000                     ||  2,000,000     ||                  ||
|-
|-
                           | DIO                       ||  1,000,000                     ||  2,000,000     ||   
                           | DIO                                   ||  1,000,000                       ||  2,000,000     ||  ||
|-
                          | cosmics                                ||  ?                              ||  -              ||                  || about 40 Mu2e livetimes generated with CRY, rescale flux with Corsika, no need to do mixing
|-
|-
                           | cosmics                   || ?                           || -              || about 40 Mu2e livetimes generated with CRY, rescale flux with Corsika, no need to do mixing
                           | RPC  external                          ||  1,000,000,000                   ||   ?             || || number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
|-
|-
                           | RPC  external             || 1,000,000,000                            ||  ?       || number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
                           | RPC  external test v1                ||                                 ||  ?             || [https://mu2e.fnal.gov/public/hep/computing/Stntuple/cafdfc/su2020/index.shtml SU2020 stntuples] || generated by Leo Borrel
|-
|-
                           | RPC internal             || 1,000,000,000                           ||    ?       ||number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
                           | RPC internal                           || 1,000,000,000                   ||    ?           ||  || number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
|-
|-
                           | RMC external             || 5,000,000                           ||    10,000,000     || flat gamma in [85,93], negligible but comes from free from mu- --> e+ background dataset
                           | RMC external                           || 5,000,000                       ||    10,000,000 || || flat gamma in [85,93], negligible but comes from free from mu- --> e+ background dataset
|-
|-
                           | RMC internal             || 5,000,000                             ||  10,000,000       ||flat gamma in [85,93], negligible but comes from free from mu- --> e+ background dataset
                           | RMC internal                           || 5,000,000                       ||  10,000,000   || || flat gamma in [85,93], negligible but comes from free from mu- --> e+ background dataset
|-
|-
                           | antiprotons               || 100,000,000,000                  ||  -            || number of generated POT, weight with cross section*sqrt(acceptance) to optimize satistical error, no need to do mixing  
                           | antiprotons                           || 100,000,000,000                  ||  -            || || number of generated POT, weight with cross section*sqrt(acceptance) to optimize satistical error, no need to do mixing  
|-
|-
                           | decays in flight   and gamma conversions       || ?                         ||  ?     || negligible in CD3
                           | decays in flight and gamma conversions || ?                               ||  ?             || || negligible in CD3


|}
|}

Revision as of 22:59, 17 June 2020

Datasets for '2020 Mu2e sensitivity updates (in progress)

  • SU2020 stands for "'2020 Mu2e sensitivity Updates"
  • consider two channels - mu- --> e- and mu- --> e+
  • signal windows are different, roughly speaking, [103.5-105] MeV/c and [90.5-92.5] MeV/c , so some background datasets could be the same, but some - unique for a given signal channel

mu- --> e- channel

Dataset N(generated events) signal-only N(events) mixed STNTUPLE dataset comments
CE (mu-Al --> e-Al) 1,000,000 2,000,000
DIO 1,000,000 2,000,000
cosmics ? - about 40 Mu2e livetimes generated with CRY, rescale flux with Corsika, no need to do mixing
RPC external 1,000,000,000 ? number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
RPC external test v1 ? SU2020 stntuples generated by Leo Borrel
RPC internal 1,000,000,000 ? number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
RMC external 5,000,000 10,000,000 flat gamma in [85,93], negligible but comes from free from mu- --> e+ background dataset
RMC internal 5,000,000 10,000,000 flat gamma in [85,93], negligible but comes from free from mu- --> e+ background dataset
antiprotons 100,000,000,000 - number of generated POT, weight with cross section*sqrt(acceptance) to optimize satistical error, no need to do mixing
decays in flight and gamma conversions ? ? negligible in CD3

mu- --> e+ channel

Dataset N(generated events) signal-only N(events) mixed comments
CE (mu-Al --> e+Al) 1,000,000 2,0000,000
DIO -> brem --> e+ 1,000,000 2,000,000
cosmics ? - ~40 Mu2e livetimes generated with CRY, rescale flux with Corsika, no need to do mixing
RPC external 1,000,000,000 ? number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
RPC internal 1,000,000,000 ? number of generated POT, pion decay disabled, weight depending on proper time, need for mixing under investigation
RMC external 5,000,000 10,000,000 flat gamma in [85,93], number of generated POT , most important after cosmics
RMC internal 5,000,000 10,000,000 flat gamma in [85,93], number of generated POT , most important after cosmics
antiprotons 10,000,000,000 - number of generated POT, weight with cross section*sqrt(acceptance) to optimize satistical error, no need to do mixing
decays in flight and gamma conversions ? - expected to be very small