User:Hcao: Difference between revisions

From Mu2eWiki
Jump to navigation Jump to search
Line 49: Line 49:


It is a 3-inch right-cylindrical cerium and strontium co-doped lanthanum bromide scintillating crystal detector, readout using a Hamamatsu R10233 PMT.
It is a 3-inch right-cylindrical cerium and strontium co-doped lanthanum bromide scintillating crystal detector, readout using a Hamamatsu R10233 PMT.
The energy deposited by each photon in the HPGe detector is used to generate a waveform according28
to the deposited ionizing energy, measured gain, and collection efficiency. Waveforms29
from different photons are superimposed using the expected time and energy distribution.30
Electronic noise from the pre-amplifier and amplifier is added. The resulting waveforms31
are digitized using the 16bit ADC, and are used together to form STMWaveformDigis. A32
similar technique will be used for LaBr response.

Revision as of 13:35, 3 July 2024

STM

Introduction of STM(Stopping Target Monitor)

The mu2e experiment measures [math]\displaystyle{ \mu^-Al\rightarrow e^-Al }[/math] process with a single event sensitivity,

[math]\displaystyle{ R_{\mu e} = \frac{Neutrinoless\ \mu\ to\ e\ conversion\ (CLVF)}{All\ \mu\ captured\ by\ Al\ nuclei\ at\ the\ stopping\ target } }[/math] or [math]\displaystyle{ R_{\mu e} = \frac{\varGamma (\mu^- + A(Z,N) \rightarrow e^- + A(Z,N)) }{\varGamma(\mu^- + A(Z,N) \rightarrow \nu _\mu + A(Z-1,N) ) } }[/math].

The goal of the STM is getting the number of stopped muons with 10% precision, so that the systematic error in the captured muon number is small enough compared with the statistical error in the number of muon-converted-electron.

Three transitions are utilized.

1) 347 keV, 2p-1s X-ray, 79.8% of muon stops. X-rays emitted when the muon comes to rest in the Stopping Target and is captured into atomic orbit (atomic capture). They are prompt signals with O(ps).

2)1809 keV gamma-ray, 51% of muon nuclear capture after muon stops. 61% of stopped muons are captured by the nuclei. These exhibit timing characteristics of the muonic lifetime ([math]\displaystyle{ \tau = 864 ns }[/math]).

3)844 keV gamma-ray 9.3% of muon nuclear capture after muon stops. The process leading to its emission is [math]\displaystyle{ \mu^- + ^{27}Al\rightarrow \nu _\mu + ^{27}Mg }[/math]. [math]\displaystyle{ ^{27}Mg }[/math] has a lifetime of 13.6 minutes. This line is appealing because of its time characteristics because it can be measured in the low background time during 1 second beam-off period in the 1.4 second main injector/recycler ring cycle.

Introduction of STM signals, X rays (347 keV )and gamma rays (844 keV and 1809 keV).

Position and Shielding of STM

STM Shielding House.

Because the strong radiation flash (consisting of muons, electrons, neutrons, X-rays and gamma-rays) overwhelms the electronic rate capability and causes radiation damages to detectors, the STM detectors need to be protected in several ways.

(1) STM is placed ~35 m away from the stopping target, not in the Detector Solenoid.

(2)A shielding house with small collimator apertures is built.

(3)Polyethylene absorbers are placed inside of the Detector Solenoid and in front of the HPGe detector.

Position of STM in the Mu2e Hall.

STM Detectors

Two STM detectors in the STM Shielding House, the HPGe detector and the LaBr3 detector.

Two detectors are used to measure the X rays and gamma rays generated by the stopped muons. One of them, the LaBr3 detector, is capable of high rate operation up to and above 800 kcps with energy resolution 0.7%. The other, the HPGe detector is capable of energy resolution of 0.1%, however its rate capability is limited to ∼70 kcps.

Details of the detector geometries and materials can be found in docdb-49130. Details of the detector resolution can be found in docdb-36803.


HPGe (High Purity Germanium) Detector

It is a GMX70P4-95-AS Gamma-X HPGe Coaxial Detector.

LaBr3 (Lanthanum(III) bromide) Detector

It is a 3-inch right-cylindrical cerium and strontium co-doped lanthanum bromide scintillating crystal detector, readout using a Hamamatsu R10233 PMT.


The energy deposited by each photon in the HPGe detector is used to generate a waveform according28 to the deposited ionizing energy, measured gain, and collection efficiency. Waveforms29 from different photons are superimposed using the expected time and energy distribution.30 Electronic noise from the pre-amplifier and amplifier is added. The resulting waveforms31 are digitized using the 16bit ADC, and are used together to form STMWaveformDigis. A32 similar technique will be used for LaBr response.