User:Hcao

From Mu2eWiki
Revision as of 17:44, 17 June 2024 by Hcao (talk | contribs)
Jump to navigation Jump to search

STM

  • Introduction of STM

[math]\displaystyle{ R_{\mu e} = \frac{Neutrinoless\ \mu\ to\ e\ conversion\ (CLVF)}{All\ \mu\ captured\ at\ the\ Al\ stopping\ target } }[/math]

[math]\displaystyle{ R_{\mu e} = \frac{\varGamma (\mu^- + A(Z,N) \rightarrow e^- + A(Z,N)) }{\varGamma(\mu^- + A(Z,N) \rightarrow \nu _\mu + A(Z-1,N) ) } }[/math]


Introduction of STM signals, X rays (347 keV )and gamma rays (844 keV and 1809 keV).
  • Position of STM
Position of STM in the Mu2e Hall.
  • STM Detectors
Two STM detectors in the STM Shielding House, the HPGe detector and the LaBr3 detector.


Two detectors are used to measure the X rays and gamma rays generated by the stopped muons. One of them, the LaBr3 detector, is capable of high rate operation up to and above 800 kcps with energy resolution 0.7%. The other, the HPGe detector is capable of energy resolution of 0.1%, however its rate capability is limited to ∼70 kcps.

The plots of STM detectors in the shielding house can be found in the link below. [[ https://mu2einternalwiki.fnal.gov/wiki/STM_Offline | Link to validation plots of STM in the Mu2e Offline ]]

Details of the detector geometries and materials can be found in docdb-49130. Details of the detector resolution can be found in docdb-36803.